Sale of maintenance testers
Magnetische Prüfanlagen GmbH sells the following
maintenance testers in Germany:
Conductivity measurement device
SIGMATEST 2.069
incl.
accessories
Crack tester
DEFECTOMETER 2.837
incl. accessories
Rivet tester
RIVET CHECK 2.839 |
|
Measurement of Electrical Conductivity |
|

More information about electrical conductivity measurement with the Sigmatest
2.069
(pdf-file 0,5 MB)
|
Electrical Conductivity Measuring Instrument - SIGMATEST 2.069
|
|
Fast and reliable determination of electrical conductivity of non
ferrous materials with high accuracy |
|
|
Large measuring range 0,5 to 65 MS/m (1 % to 112 % IACS) |
|
|
5 selectable operating frequencies (60, 120, 240, 480, 960 kHz) |
|
|
Integrated distance correction for measurements on painted, coated
or dusty surfaces with a thickness up to 500 µm |
|
|
High measuring accuracies also for materials with a very low thickness
|
|
|
Adjustable measurement rate, 1-20 measurements per second |
|
|
Temperature compensation using an internal or an external temperature
sensor and with a user defined temperature coefficient
|
|
|
Multilingual operating system |
|
|
Data transfer to PC via compact flash card, RS-232 connection or
ethernet
Remote Software SigmatestXP
for comfortable data transfer via RS-232 interface |
|
|
Remote control via RS-232 connection or via Ethernet |
|
|
Robust housing for measurements on site |
|
|

Technical Leaflet
(pdf-file 1 MB) |
Crack detection instrument
DEFECTOMETER M 1.837
The DEFECTOMETER M 1.837 is designed for crack testing. It is characterised by a very high sensitivity to surface defects and by simple, intuitive operation.
Compared to the predecessor model, the DEFECTOMETER 2.837, it has numerous new features. >> more... |
|
 |
Crack tester DEFECTOMETER 2.837
incl. accessories
Technical data
Defect resolution: Up to approx. 20 µm
Dyn. of sensitivity: 20 dB in 0.5 dB intervals
Zero offset: From 0 to 100 scale divisions
Defect thresholds: Two, can be adjusted and deactivated
Flaw indication: Optically as a field on LCD, acoustically
via loudspeaker or headphones. As analog signal at the output
bushing
LCD: 128 x 128 pixels with background illumination (with
on/off function),
high contrast in sunlight
Power supply: 3 x monocells or 3 x NiCd batteries or external
power unit
Operating life with battery: > 8 h
Battery display: "BAT" warning at 10 min
remaining battery life
Degree of protection: IP 54
Weight: 0.95 kg |
|